Key takeaways
- Al₂O₃ ≥29% is a performance figure; heavy metal limits are a safety figure. A supplier can meet one and fail the other.
- Drinking water grade PAC is governed by GB 15892-2020. Industrial grade follows GB/T 22627-2022 and permits far higher impurity levels.
- Coagulants are dosed directly into raw water at 10–50 mg/L. Over a year, that is thousands of tonnes of chemical passing through a utility — impurities accumulate in the distribution system and in sludge.
- Always verify with a per-batch COA plus independent third-party testing. A one-off type test from three years ago proves nothing about the container arriving next month.
Why Al₂O₃ content is the wrong question on its own
Most procurement enquiries we receive open with a single number: "Do you have 29% or 30% PAC?" That is a reasonable starting point — aluminium oxide content determines how much product you need per cubic metre of water, and therefore your cost per tonne treated. But it answers only half the question a water utility actually needs answered.
Poly aluminium chloride is manufactured by reacting alumina-bearing raw material with hydrochloric acid, then adjusting basicity through controlled neutralisation. Everything that enters those raw materials — trace metals in the bauxite or kaolin, impurities in the acid, contamination in process water, corrosion products from the reactor — ends up distributed through the finished product. Higher Al₂O₃ purity and lower heavy metal content are related but not the same thing. You can concentrate aluminium content while still carrying lead and arsenic through the process.
For industrial effluent or mining tailings, that distinction rarely matters. The receiving water is not destined for human consumption. For a municipal drinking water plant, it matters a great deal.
The two standards, and why the gap is wider than most buyers expect
China defines two separate product standards for PAC, and they are not interchangeable:
| Standard | Grade | Typical application | Impurity control |
|---|---|---|---|
| GB 15892-2020 | Drinking water grade | Municipal potable water, waterworks, food and beverage process water | Strict heavy metal ceilings; requires a 涉及饮用水卫生安全产品卫生许可批件 (hygiene licence) to sell into this market |
| GB/T 22627-2022 | Industrial grade | Industrial wastewater, municipal sewage, sludge conditioning, papermaking | Permits substantially higher levels of Pb, As, Cd and Hg |
The critical point for buyers: the physical appearance is identical. Both grades are a yellow-to-light-yellow powder or a yellowish liquid. Both can be supplied at Al₂O₃ ≥29%. You cannot tell them apart in a jar test, and a supplier quoting "29% PAC" without naming the standard has told you nothing about the grade you will receive.
This is also the single most common substitution risk in this product category — industrial grade supplied against a drinking water tender, because the buyer's specification mentioned only Al₂O₃ content.
The parameters that define drinking water grade
Under GB 15892-2020, drinking water grade PAC is specified on the following basis. Confirm the exact limits against the current edition of the standard and against the batch certificate of analysis — this table is a working summary for procurement discussion, not a substitute for the standard itself.
| Parameter | Requirement | What it controls |
|---|---|---|
| Al₂O₃ content | ≥29% (solid) · ≥10% (liquid) | Coagulation performance and dose economics |
| Basicity | 40–90% | Hydrolysis behaviour, pH depression, cold-water performance |
| pH (1% aqueous solution) | 3.5–5.0 | Handling safety and compatibility with dosing systems |
| Water-insoluble matter | ≤0.6% (solid) | Membrane fouling, filter loading, post-treatment turbidity |
| Arsenic (As) | ≤0.0002% | Carcinogenic; no safe threshold in potable supply |
| Lead (Pb) | ≤0.001% | Neurotoxic; accumulates in distribution sediment |
| Cadmium (Cd) | ≤0.0002% | Nephrotoxic; bioaccumulative |
| Mercury (Hg) | ≤0.00001% | Neurotoxic; bioaccumulative |
| Hexavalent chromium (Cr VI) | ≤0.0005% | Carcinogenic |
Two parameters deserve separate attention because they are routinely overlooked:
Water-insoluble matter
This one is not a health parameter, but it is the most common operational complaint. Insoluble residue passes through coagulation and lands on downstream filters and, in membrane plants, on the membrane surface. A product at 0.6% insolubles in a 40 mg/L dose delivers measurable solids loading to a filter bed over a month. Utilities running ultrafiltration or reverse osmosis downstream of clarification should treat this limit as a hard purchasing requirement rather than a formality.
Basicity
Basicity governs how much alkalinity the coagulant consumes. Low-basicity PAC will depress pH and may require lime or caustic addition; high-basicity PAC reduces chemical demand for pH correction but can be less stable in storage and more sensitive to dilution water quality. For low-alkalinity or soft source waters — common in surface water plants in tropical and arid regions — basicity selection has a direct effect on total chemical cost, not just on coagulation efficiency.
Where the impurities actually come from
Understanding the source of contamination explains why supplier selection matters more than specification wording:
| Source | Contaminants introduced | How it is controlled |
|---|---|---|
| Alumina raw material (bauxite, kaolin, alumina hydroxide) | Pb, As, Cd, Cr, Fe | Raw material sourcing and incoming-material assay — the dominant factor |
| Hydrochloric acid | As, Fe, organics | Acid grade selection and supplier qualification |
| Process water | Whatever the local water carries | Use of demineralised or potable process water |
| Reactor and handling equipment | Fe, Cr, Ni from corrosion | Material of construction, maintenance regime |
| Packing and storage | Leachable metals, moisture pickup | Liner specification, storage conditions, batch traceability |
The practical implication: a producer using consistent, assayed raw material and demineralised process water can reliably hold drinking water limits batch after batch. A producer switching raw material sources to chase price cannot — even if the plant is nominally certified. This is why the certificate matters less than the process discipline behind it.
How to actually verify what you are buying
Four steps, in order of what catches problems earliest:
- Name the standard in the purchase order. "PAC, Al₂O₃ ≥29%, GB 15892-2020" — not "PAC 29%". This single line closes the substitution loophole.
- Require the hygiene licence. In China, selling a coagulant for potable water use requires a 涉及饮用水卫生安全产品卫生许可批件. Ask for the licence number and verify the product name and producer match the offer. This is a legal document, not a marketing claim.
- Demand a per-batch COA, not a type test. A laboratory report dated three years ago describes a batch that has long since been consumed. Ask for the COA covering the specific batch and container numbers on your shipping documents.
- Run independent verification on first delivery and periodically thereafter. SGS, CCIC or an accredited local laboratory. Test at minimum Al₂O₃, basicity, insolubles, As, Pb, Cd and Hg. The cost is trivial relative to the risk of a non-conforming chemical entering a potable supply.
A note on the "30%" figure. Overseas buyers frequently ask for "30% PAC". That number comes from an earlier edition of the standard and from common trade shorthand. The current drinking water requirement is expressed as Al₂O₃ ≥29%. If your historical dosing calculations were built on 30%, convert the dose by the ratio of actual to assumed content rather than treating the two as identical products.
How Hua Quan controls drinking water grade quality
Henan Hua Quan Water Treatment Materials Co., Ltd. has manufactured coagulants since 1982 and holds the 涉及饮用水卫生安全产品卫生许可批件 for drinking water grade poly aluminium chloride. Relevant credentials for buyers evaluating this product line:
- Standard participation: the company is a drafting unit for GB 15892-2020 (drinking water grade PAC) and GB/T 22627-2022 (industrial grade PAC), alongside its role as a long-standing producer.
- Quality systems: ISO 9001 and ISO 14001 certified, with SGS and CCIC inspection available on request.
- Production capacity: six manufacturing bases, with annual output of approximately 40,000 tonnes of water treatment chemicals and 30,000 tonnes of filter media.
- Specification discipline: two PAC grades only — industrial grade at Al₂O₃ ≥28% to GB/T 22627-2022, and drinking water grade at Al₂O₃ ≥29% to GB 15892-2020. No intermediate or relabelled grades.
- Batch traceability: per-batch COA issued with shipment; third-party testing arranged at the buyer's nominated laboratory on request.
For utilities and EPC contractors, we supply jar-test support before order confirmation and dosing optimisation input after commissioning — because the correct grade is only half the answer, and the correct dose for your specific raw water is the other half.
Need drinking water grade PAC with a verifiable COA?
Tell us your raw water characteristics, target turbidity and plant capacity. We will confirm the grade, propose a dose range and send documentation — usually within one working day.
This article is a technical summary for procurement and engineering reference. Always verify requirements against the current edition of the applicable standard and your local drinking water regulations. Product specifications are confirmed on the batch certificate of analysis.