Ask three activated carbon suppliers for a gold circuit quote and you will get three datasheets headed by iodine number. It has become the default quality proxy because it is cheap to run, standardised (ASTM D4607) and easy to compare. The problem is that a gold plant does not adsorb iodine — it adsorbs aurocyanide complex ions from a slurry that is simultaneously trying to blind the carbon with calcium carbonate, oil, flotation reagents and fine clays.
Iodine number is measured in clean water with a small molecule. Gold loading happens in dirty water with a large, linear, strongly solvated ion. The two tests ask different questions, and the gap between them explains most of the discrepancy between "premium specification carbon" and "carbon that actually performs".
| Property | What it measures | Relevance to CIP/CIL | Typical coconut shell value |
|---|---|---|---|
| Iodine number (ASTM D4607) | Micropore volume, pores below 2 nm, in mg/g | Indirect. Confirms the carbon is well activated, but says nothing about kinetics in pulp | 1,000–1,150 mg/g |
| K-value (adsorption rate) | Rate constant from a standard gold solution over a fixed contact time | High. Directly predicts how many tanks you need for a given recovery | Reported as a time to reach 50% loading; lower is better |
| Equilibrium gold loading | Maximum Au adsorbed per unit mass at equilibrium concentration | High. Sets the strip frequency and the carbon inventory | 20–40 kg Au/t at typical circuit conditions |
| Hardness / abrasion resistance | Resistance to attrition under slurry agitation | Very high. Drives carbon consumption, which is usually the largest single operating cost | Hardness ≥ 95%, abrasion loss ≤ 3% |
| Apparent density | Mass per unit bulk volume, g/cm³ | Sizing of screens, tanks and transfer systems | 0.45–0.55 g/cm³ |
| CTC adsorption | Carbon tetrachloride activity, % | Vapour-phase indicator. Marginal relevance to hydrometallurgy | 50–70% |
The table is ordered roughly by how much each property should influence your purchase decision for a gold circuit. Notice that iodine number, the property printed largest on most datasheets, sits in the middle at best.
Carbon in a CIP/CIL circuit is a consumable, not a fixed asset. It is lost three ways: attrition fines that pass the interstage screens, carbon burned or degraded in the regeneration kiln, and physical loss during transfer and handling. Across a typical operation, these add up to somewhere between 10 and 40 grams of carbon per tonne of ore processed, and that figure — not the purchase price per tonne — is what dominates the annual carbon budget.
This produces a counter-intuitive conclusion. A carbon at 1,150 mg/g iodine with 92% hardness can cost more per year than one at 1,050 mg/g with 96% hardness, even at a higher purchase price for the harder product. The harder carbon loses fewer fines, so the effective cost per unit of gold recovered is lower.
How to check this yourself. Ask both suppliers for the abrasion loss figure and the test method used (ASTM D4058 is common, but some suppliers quote an in-house ball mill test that is not comparable). If two suppliers quote abrasion loss with different methods, the numbers cannot be compared, and you should ask both to run the same method on the same sample.
Most CIP/CIL circuits run 6×12 mesh (approximately 1.7–3.35 mm) carbon. The choice between 6×12 and 8×16 is usually inherited from the original plant design rather than re-evaluated, but it materially affects performance.
| Mesh size | Approximate particle range | Advantage | Trade-off |
|---|---|---|---|
| 6×12 | 1.70–3.35 mm | Better screen retention, lower fines loss, easier elution and regeneration | Slower adsorption kinetics — needs longer residence time |
| 8×16 | 1.00–2.36 mm | Faster kinetics, higher loading per unit residence time | Higher attrition loss, more prone to screen blinding |
| 12×30 | 0.60–1.70 mm | Very fast kinetics, used in some resin-in-pulp conversions | High loss rate, generally uneconomic in conventional CIP |
The practical rule: if your circuit is residence-time limited, finer carbon buys you recovery. If your circuit is carbon-loss limited — which is more common — coarser carbon saves money. Measure your screen undersize loss before deciding.
Regenerated carbon is not fresh carbon, and treating the two as interchangeable is a frequent source of unexplained recovery loss. Thermal regeneration in a rotary kiln at around 650–850 °C in a steam atmosphere removes the organic loading from the pore structure. Under good conditions it recovers 90–95% of the original activity. Under poor conditions — insufficient temperature, wet feed, excessive residence time — it can recover far less, and the carbon comes back with a reduced pore volume that no certificate will flag.
Three practices worth insisting on:
Most carbon purchase disputes trace back to a specification that listed iodine number and mesh size and nothing else. A specification that actually protects the buyer includes:
Items 3 and 5 are the ones most often omitted and the two that matter most in operation.
Hua Quan produces coconut shell, coal based and columnar activated carbon with iodine number from 900 to 1,100 mg/g, in granular form for CIP/CIL and powder form for refining and tailings polishing. Acid-washed grades are available for circuits where calcium leaching is a concern. Each batch ships with iodine number, hardness, apparent density and moisture, and we retain a sample from every lot against future dispute.
Our carbon is produced under ISO 9001 and ISO 14001 certified processes, and we can supply SGS or CCIC third-party verification on request when a buyer's procurement rules require it.
Send us your circuit parameters — ore throughput, tank residence time, target loading and screen size — and we will quote a specification matched to your constraint, with hardness and K-value data attached rather than iodine number alone.
Loading capacities, abrasion figures and regeneration recovery rates in this article are typical industry values for guidance only. Actual performance depends on ore mineralogy, leach chemistry, circuit configuration and kiln operation. Confirm by plant trial against a retained reference sample before changing specification.